Sensus Unipro Software Download

• This document contains proprietary information. It is to be used only for the purpose for which it is intended. Information in this document is subject to change without notice and does not represent a commitment on the part of Sensus USA, Inc. No part of this publication may be reproduced, transmitted, stored in a retrieval system, or translated into any language in any form by any means, with- out the written permission of Sensus. • 2.4 Replacing an Existing Meter.. 2-2 3 Programming..3-1 3.1 Programmable Parameters.. Arta succesului pavel corut pdf download.

Unipro

20130531 - 5.8 - 1 iPERL System (DS-W-IPL--04-A) - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Scribd is the world's largest social reading and publishing site.

3-1 3.2 Connecting the iPERL System to a PC.3-2 3.3 Setting Default Parameters in Unipro.3-4 3.4 Programming the iPERL System..3-8 4 Reporting.. • The iPERL system’s body is comprised of a composite material ensuring that it is 100% lead free and stable across a wide range of temperatures. The iPERL system contains an electronic register with embedded AMI functionality. • If, for any reason, the system loses power, the system is able to be powered through the touch couple to retrieve the last reading.

1.3.3.5 Memory and/or Self Monitoring Alarms The iPERL system is equipped with self monitoring alarms that detect and report any memory failures. 1.3.4 Leak Detection Leak detection is defined as the absence of the transition from active flow to below the defined starting flow over a configurable time interval. • The system reading may be reset via the bi-directional TouchRead® connection. 1.4 iPERL System Display The iPERL system display is a fully electronic display with embedded AMI technology. Figure 1-2 shows the different components of the iPERL system display. Figure 1-2: iPERL System Display 1.

• 2.3 Installing a New iPERL System The iPERL system is designed to be installed in either an outdoor pit setting or in an indoor basement setting. To install a new iPERL system: 1.

Record read information as required by the utility. 2.4 Replacing an Existing Meter To replace an existing meter with the iPERL system: 1. Unpack the new iPERL system from the packaging. Inspect the system for any parts that may have been damaged during shipping. Check the read on the system to make sure it is registering a positive number. If it is not, make sure the system is installed in the correct direction.

Attach an endpoint to the system via a coupler cable. Record read information as required by the utility. Drm key download. IPERL Water Management System Technical Manual WRMTM-40001. • How to program the iPERL system. 3.1 Programmable Parameters Certain features of the iPERL system may be programmed using the Sensus Universal Programmer (Unipro™) software application.

Table 3-1 describes the parameters on the iPERL system that may be programmed. Table 3-1: Programmable Parameters. • 3.2 Connecting the iPERL System to a PC You will need an OMNI Communicator 100A and drivers to connect the iPERL system to your PC. To obtain these tools, please see your Sensus representative. To connect the iPERL system to your PC: 1. • The Connection Settings screen appears, as shown in Figure 3-2.